SunRay Quad

Large-area UV flood curing system

Expand AllCollapse
SunRay Quad Product Summary

The SunRay Quad is a large-area UV light-curing flood lamp system. All components are integrated into a single unit that can be easily mounted on the optional Rayven Quad benchtop curing chamber or anywhere on a factory floor with virtually no cabling or remote power boxes required. Just mount the lamp head, connect the AC line cord and start timed exposure curing.

The four long-life arc lamps and parabolic reflectors illuminate a 16 x 12” curing area with evenly distributed UV light. The arc lamps are powered by the state-of-the-art UV Power-Plus Lamp Driver.

For a compact version of this system, see the SunRay.

Additional Details

Lamp power regulation: The system’s switch mode power supply maintains constant lamp power regardless of variations in AC line input or lamp voltages. This regulation provides for repeatable curing times and longer lamp life.

Standby mode: The unit features a standby mode rocker switch, which reduces lamp power when the system is idling. This mode can be used to reduce heat and stray UV light output while the system is not in use.

Front panel display and indicators: A front panel hour meter tracks lamp age, allowing for consistent lamp replacement scheduling. Lamp fault and system power-on LEDs provide system status information.

External logic signal interface: The system can be remotely monitored and controlled using logic signals available at a D-sub connector on the unit’s rear panel. Available signal types are:

  • Lamp standby input for variable PWM control of lamp intensity, or for minimizing of lamp power during idle periods
  • Lamp-out indicator activates if any lamp has extinguished
  • Hour meter reset input for zeroing hours display after lamp replacement
  • 24VDC at 2A output for powering external fans, relays, solenoids or motors

Forced air cooling: Variable speed cooling fans with removable filters direct air to critical system components, ensuring cool operation and high system reliability.

Best-in-class lamp life: The enhanced lamp life of the system rivals even microwave and LED systems, significantly lowering operating and maintenance costs.

Accessories & Options

Optional lamp spectrums: The SunRay Quad is available with UVA, UVB and visible spectrum lamps ensuring compatibility with adhesives and coatings from all manufacturers.

 

Dimensions & Specs
SunRay Quad Specifications
System TypeParabolic Flood Curing System
Part #UV2842
Lamp Power2400W (4 x 600W)
Input Voltage200–240 VAC ±10%
Input Current (Max)16 Amps
Irradiance @ 4"110 mW/cm2 UVA, typical
Curing Area16 x 12"
Weight24.5 lbs
Size (L x W x H)17.45 x 23 x 7.75”
Accessories Part Numbers
Part No.ItemDetails
UV2875Rayven QuadShielded Curing Chamber w/ shutter door interlock
UV2605Quad Flood Filter GlassReplacement filter glass for SunRay and IntelliRay Quad floods. Filters shortwave and infrared wavelengths
UV0526Logic Remote Interface CableControl from PLC or digital logic
(Multiple)Power cordsMultiple types available
(Multiple)UV Curing TrayStainless steel non-stick surface
UV1450-xxUvicure Plus II Integrating RadiometerUVA, UVB or Visible ranges, 10–10,000mW/cm2
UV0495UV/IR Protective Safety GlassesOTG (fit over prescription eyewear), 3.0 shade
UV02231UV/IR Protective Safety GlassesSport contour, 3.0 shade
UV01889UV Protective Face ShieldLift-up face shield ideal for maximum UV/Visible light protection, 4.0 shade
Replacement Lamps:
UV0834UVA Metal Halide Lamp600W medium pressure
UV1884UVB Enhanced Lamp600W medium pressure
UV1074Visible Metal Halide Lamp600W medium pressure, 420nm
SunRay Quad

Request Quote for SunRay Quad

Request a quote for the version of the SunRay Quad flood system that best fits your needs.

Below you can choose from the different available models, components and accessories for this system. You can select each item one at a time or begin with the Default Configuration as a basis, and build from there.

If you have any questions contact us directly.

Quote Default Configuration
Remove System from Quote
UV2842 - SunRayQuad-1,SRayQuadLamps-1,SRayQuadUV2875-2
UV2842-NL - SunRayQuad-1,SRayQuadLamps-2,SRayQuadUV2875-2
UV2842-NL - SunRayQuad-1,SRayQuadLamps-3,SRayQuadUV2875-2
UV2842-NL - SunRayQuad-1,SRayQuadLamps-4,SRayQuadUV2875-2
UV2842 - SunRayQuad-1,SRayQuadLamps-1,SRayQuadUV2875-1
UV2842-NL - SunRayQuad-1,SRayQuadLamps-2,SRayQuadUV2875-1
UV2842-NL - SunRayQuad-1,SRayQuadLamps-3,SRayQuadUV2875-1
UV2842-NL - SunRayQuad-1,SRayQuadLamps-4,SRayQuadUV2875-1

System Type and Included Items

The default SunRay Quad configuration comes with Flood Filter Glass, four 600 Watt UVA enhanced arc lamps, pair of UV/IR protective OTG glasses (3.0 shade with case), pair of Cotton Knit Work Gloves (large size, UV protective), AC power cord (USA standard), two Small Rubber Suction-cup Lifter and SunRay Quad Manual.

SunRay Quad - UV2842-NL

Large area economical flood curing system. UVA lamps included by default unless otherwise selected below.

Choose Lamp Type

The SunRay Quad is available with UVA, UVB & visible spectrum lamps, ensuring compatibility with adhesives and coatings from all manufacturers.

600W UVA lamps (4 req'd) - UV0834

Four 600W UVA enhanced arc lamps for SunRay Quad system

600W UVB lamp (4 req'd) - UV01884

Four 600W UVB enhanced arc lamps for SunRay Quad system

600W Visible lamp (4 req'd) - UV1074

Four 600W Visible enhanced arc lamps for SunRay Quad system

Choose Mounting & Shielding Option

The default Quad Rayven configuration comes with an adjustable height shelf, a male to female 15 position DSUB lamp interconnect cable and a Quad Rayven Instruction Sheet.

Rayven Quad - UV2875

UV shielded curing chamber for IntelliRay & SunRay Quad floods

No Mounting or Shielding Options

This option removes the Rayven Quad chamber

Accessories

Click to add any accessories below that you would like included in your quote. To view or price more accessories or replacement parts, visit our online store.

UVICure Plus II Radiometer - UV1450-MA

Single Channel, Mid Power Radiometer to monitor SunRay Quad intensity output in the UVA (320-390 nm) bandwidth. Ideal for UVA enhanced lamps. For other spectral types visit online store.

IS310 UV Logger - UV4007

Single Channel, Economical Profiling Radiometer to monitor SunRay Quad intensity output in the UVA & UVB (280-400 nm) bandwidths. For other radiometer types visit online store.

UV Protective Face Shield - UV1889

Lift-up face shield, ideal for maximum UV/Visible light protection, 4.0 shade.

Stainless Steel Curing Tray - UV4269

Versatile stainless steel UV curing tray used with Rayven chamber for custom curing applications. Dimensions: 16" x 12" x 1"

Add to Quote

Quote Sheet

X
*NOTE: The quote sheet is separate from your shopping cart. This is for submiting a quote request for our Custom Systems.
Quote Cart